Power Distribution Unit PDU12 (220V UK 12 ways)
Availability: In Stock
Power Distribution Unit PDU12 (220V UK 12 ways)12 Way UK Type BS1363 SocketsMaster on /off switchPower Distribution Unit PDU12 (220V UK 12 ways)Socket Type: BS1363 (90degree) Outlet ModuleUK TypeSocket Quantity: 12 wayInput Cable: 2 MeterMaster Switch: YesSurge Protection: NoRating Current: 13 AmpRating voltage: 250VAC 50/60HzCE Approved: YesMax. Power: 3250WLength: 970 mmHeight: 44.4 mm (1U)Depth: 62 mmColor: BlackRoHS: Yes 1. Collection from SGCCTV Choicecycle Sim Lim Square CCTV SPECIALIST #02-81 11am~8pm. Whatsapp 90254466 for stock level before visit.2. Payment by PayNow 201207820G (Please print screen and whatsapp to 90254466) & Paylah QR code will receive Free Gift Warning Stickers worth $20.00 (1pc per client order)3. Please add $18.00 for delivery - 3~5 days, no further discount as Price guarantee lowest.4. Can issue e-Invoice for your accounting. (upon request)Power Distribution Unit PDU12 (220V UK 12 ways)SGCCTV-PDU12 12-Way Power Distribution Unit with Auto Circuit Breaker for 42U Server Rack SingaporeThe SGCCTV-PDU12 is a 12-way rack Power Distribution Unit (PDU) designed for vertical installation inside 42U server racks, CCTV racks and network cabinets.Its purpose is to provide centralized AC power distribution for rack-mounted equipment while incorporating an automatic circuit breaker for overload protection.Key FeaturesFeatureSGCCTV-PDU12ProductRack Power Distribution Unit (PDU)ModelSGCCTV-PDU12Power Outlets12-WayInstallationVertical Rack InstallationRack Application42U Server Rack / Network RackProtectionAuto Circuit BreakerApplicationCCTV, NVR, Server, Network & IT EquipmentMounting ConceptVertical / Zero-U style installationPower DistributionCentralized AC supply to rack equipmentElectrical ratings such as input voltage, maximum current, breaker rating, socket type, cable size and plug type should be published according to the exact SGCCTV-PDU12 production specification.Why Install the PDU Vertically in a 42U Rack?A vertical PDU is particularly useful in a full-height 42U server rack because it can be mounted along the side or rear of the cabinet instead of consuming valuable horizontal rack space.Horizontal PDUMay occupy 1U or more of equipment space.SGCCTV-PDU12 Vertical PDUMounted vertically inside the rack, helping preserve rack units for:NVRs • Servers • PoE Switches • Firewalls • Fiber Equipment • Patch Panels • UPS SystemsThis is commonly described as a Zero-U PDU arrangement, provided the rack has suitable vertical mounting space.12-Way Centralized Power DistributionOne PDU can provide organized power distribution to multiple rack devices.Typical 42U CCTV/network rack:UPS↓ SGCCTV-PDU12↓NVRPoE SwitchCore Network SwitchFortinet FirewallFiber SwitchKVMServerMonitor/Console EquipmentThis is substantially cleaner than installing multiple domestic extension sockets throughout a professional equipment rack.Auto Circuit Breaker ProtectionThe integrated auto breaker provides an additional protective point for the PDU circuit.If an abnormal overload occurs, the breaker is intended to disconnect the circuit rather than allowing excessive current to continue through the PDU.However, a PDU circuit breaker should not be treated as a replacement for the building's correctly designed electrical protection.A professional rack should consider:Upstream MCB/RCBO/RCCB → UPS → Rack PDU → IT Equipmentdepending on the site's electrical design and equipment requirements.Recommended with UPSFor critical CCTV, network and server applications, the PDU can be installed downstream of a properly sized UPS:230VAC Supply↓Electrical Protection↓ UPS↓ SGCCTV-PDU12 12-Way PDU↓NVR + Switch + Firewall + Server + Network EquipmentThis provides centralized rack distribution while the UPS supplies backup power to the connected critical equipment.The UPS capacity must be calculated from the actual combined load, required runtime and future expansion.Ideal for CCTV Equipment RacksThe SGCCTV-PDU12 is suitable for organizing power to:HIKVISION NVRDAHUA NVRHanwha Vision NVRPoE Network SwitchesRUIJIE Network SwitchesFortinet FirewallFiber Media EquipmentKVM SwitchesCCTV ServersAccess-Control Network EquipmentRack Cooling AccessoriesOther compatible IT equipmentProfessional 42U Rack DesignA typical CCTV/server rack can be arranged as:42U SERVER RACKTopFiber Patch PanelCat6 Patch PanelCable ManagementCore Network SwitchPoE SwitchesFirewall / RouterNVR / VMSServersKVMUPSBattery EquipmentBottomVertical Side / Rear:SGCCTV-PDU12 12-Way PDUThis keeps AC power distribution separated and organized while preserving front rack space.PDU Load Calculation Is ImportantDo not determine PDU suitability simply by counting the number of outlets.For example, having 12 outlets does not mean 12 high-power devices can automatically operate at maximum load simultaneously.The calculation should consider:Total Equipment WattagePDU Rated CurrentCircuit Breaker RatingInput Plug RatingSupply Circuit RatingUPS Output CapacityCable RatingContinuous Operating LoadFor professional installations, the PDU's electrical rating must be equal to or greater than the designed load and must remain within applicable electrical requirements.CCTV Rack ExampleFor a commercial CCTV system:Fortinet Firewall↓RUIJIE Core / Managed Switch↓PoE Switches↓HIKVISION / DAHUA NVR↓Storage / VMS ServerPower architecture:Building AC↓UPS↓ SGCCTV-PDU12↓Firewall + Switches + NVR + ServerThis provides a much more organized approach to rack power management.PDU vs Ordinary Extension SocketFor a professional 42U server rack, a rack-mounted PDU provides several practical advantages over loose consumer extension strips:Secure Rack InstallationCleaner Cable ManagementCentralized Power DistributionDedicated Rack LayoutIntegrated Circuit ProtectionReduced Loose Power Adaptors and Extension StripsEasier MaintenanceBetter Equipment IdentificationA properly installed rack should make both the network path and power path easy for technicians to trace.Recommended Installation PracticeFor a professional installation:1. Calculate the total rack load2. Confirm PDU maximum current and breaker rating3. Confirm UPS capacity4. Mount PDU vertically inside the 42U rack5. Separate AC power cables from data/fiber where practical6. Label each PDU outlet7. Avoid cascading extension strips8. Keep cables properly dressed and secured9. Leave allowance for future equipment10. Document which PDU outlet supplies each rack deviceExample:PDU-01 → FirewallPDU-02 → Core SwitchPDU-03 → PoE Switch 1PDU-04 → PoE Switch 2PDU-05 → NVR 1PDU-06 → NVR 2This greatly simplifies future troubleshooting.Where to Buy SGCCTV-PDU12 in Singapore?For SGCCTV rack PDU, 42U server rack, UPS, network switches, CCTV NVR, rack installation and structured network solutions in Singapore, contact:SGCCTV / Choicecycle CCTV Pte LtdWhatsApp: +65 98534404Email: enquiry@choicecycle.com.sgWebsite: www.sgcctv.com.sgFor project sizing, provide the 42U rack model, equipment list, equipment wattage, UPS model and required PDU quantity so the rack power distribution can be correctly planned.10 FAQs1. What is the SGCCTV-PDU12?It is a 12-way rack Power Distribution Unit intended for centralized power distribution inside a server/network rack.2. Can it be installed in a 42U server rack?Yes. The SGCCTV-PDU12 is intended for vertical installation in a suitable 42U rack.3. Does vertical mounting consume 1U rack space?When mounted in the rack's dedicated vertical PDU area, it can operate as a Zero-U-style installation, preserving horizontal equipment space.4. How many outlets does it provide?The SGCCTV-PDU12 provides 12 power outlets.5. Does it include a circuit breaker?Yes. The specified configuration incorporates an automatic circuit breaker.6. Can it be connected to a UPS?Yes, provided the PDU input specification, UPS output and total equipment load are electrically compatible.7. Can it power NVRs and network switches?Yes, subject to the PDU's electrical rating and the combined load of all connected equipment.8. Is a 12-way PDU the same as a domestic 12-way extension socket?No. A rack PDU is intended for structured equipment-rack installation and centralized rack power distribution.9. Can I connect two PDUs to a 42U rack?Yes, where the rack design and electrical capacity permit. Larger installations may use separate PDUs for different equipment groups or redundant power architectures.10. Where can I buy a 12-way vertical PDU for a 42U rack in Singapore?Contact SGCCTV / Choicecycle CCTV Pte Ltd for PDU, UPS, server-rack and CCTV/network rack solutions.15 Facebook Hashtags#SGCCTV #SGCCTVPDU12 #PDU #PowerDistributionUnit #12WayPDU #RackPDU #ServerRack #42UServerRack #NetworkRack #CCTVRack #DataCentre #RackManagement #UPS #NetworkSingapore #CCTVSingapore